Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
J Clin Virol Plus ; 3(1): 100137, 2023 Feb.
Article in English | MEDLINE | ID: covidwho-20237357

ABSTRACT

With widespread global COVID-19 vaccine coverage, a scalable, cost-effective, and standardized tool to ascertain post-vaccine immunity is a dire need. Neither clinical evaluations of vaccine efficacy, nor live virus antibody neutralization assays fulfill these criteria. Commercially available anti-S binding immunological assays have the potential to fill this gap, but need to be systematically evaluated for their utility to serve as surrogates for the aforementioned, widely accepted tools of determining vaccine efficacy. In this study, we evaluated an anti-S binding immunological assay (Roche Elecsys Anti-SARS-CoV-2 S) by utilizing two hundred and fifty-five archived serum specimens, either pre-pandemic, or those exposed to natural infections or vaccines with their neutralizing titers pre-determined through a live virus, pseudotyped antibody neutralization assay. Roche Elecsys Anti-SARS-CoV-2 S demonstrated good sensitivity (98%) and specificity (99%), just as has been reported in some other previously conducted studies using this assay. Only a mild correlation, however, with the live virus pseudotyped lentivirus antibody neutralization assay (Spearman's r = 0.26) was observed. We conclude that, as such, Elecsys Anti-SARS-CoV-2 S has a high sensitivity and specificity for detecting anti-SARS-CoV-2 S proteins, though the assay does not always correlate well with live virus assays for quantitative outcomes.

2.
Rawal Medical Journal ; 48(1):70-73, 2023.
Article in English | EMBASE | ID: covidwho-2258818

ABSTRACT

Objective: To find the trend of seropositivity of antiSARS-CoV-2 antibodies in registered patients for COVID-19 in Dow Diagnostic Reference and Research laboratory Methodology: A total of 5247 patients were enrolled for SARS CoV2 antibodies analysis from 01 August to 31 December, 2020. Patient consent was attained and questionnaire forms were filled. Samples were tested for anti-SARS-CoV-2 antibodies on (Roche Cobase 601). Result(s): In 5247 patient's samples, seropositivity of SARS CoV2 was found in 2425 (46.2%) samples. Seroprevalence in males was 28.4% (n;1491) as compared to females, who showed 17% (n;934). The age group G3 (> 46 to 60 years) showed higher seropositivity (n = 604/1118, 54%) as related to other age groups. Out of total reactive patients, only 30% (n;727) reported recent symptoms while 70% (n;1697) were asymptomatic. Fever was observed to be the most common symptom followed by dry cough. The most commonly affected areas were East 2353 (44%), South 855 (16.01%), Malir 793 (14.85%), Center zone 589 (11.03%) and Korangi area 378 (7.08%). The frequency of seropositivity showed an increasing pattern in the six months from August 2020 to December 2020. It was found to be 11.5% in August, 13.6% in September, 13.9% in October, and 42.5% in December 2020. Conclusion(s): The trend of seropositivity revealed a gradual upward course in the duration of study period. Nearly, two thirds of the patients were asymptomatic indicating the fact that many individuals were silently exposed to the infection and developed antibodies through their natural defense mechanism.Copyright © 2023, Pakistan Medical Association. All rights reserved.

3.
Vaccines (Basel) ; 10(10)2022 Sep 23.
Article in English | MEDLINE | ID: covidwho-2044039

ABSTRACT

This prospective study provides data on the long-term humoral immunogenicity of a heterologous off-label vaccine regimen combining the adenoviral-vectored ChAdOx1 nCoV-19 from Astra-Zeneca (ChAd) with the mRNA-1273 vaccine from Moderna (m1273) in comparison with two different homologous mRNA vaccine schedules. Of the 316 COVID-19 naïve adult health care workers (HCW) included to complete a survey on vaccine-associated symptoms (VAS), 197 had received the homologous BNT162b2 mRNA vaccine from Pfizer/BioNTech (BNT/BNT), 76 the homologous m1273/m1273, and 43 the heterologous ChAd/m1273 vaccine regimen. The concentration of antibodies against SARS-CoV-2 spike protein in plasma 5-7 months after the second vaccine dose was higher in the m1273/m1273 and ChAd/m1273 than the BNT/BNT vaccine group. The frequency of systemic VAS after the first vaccine dose was 86% after ChAd compared with 35% and 39% after BNT and m1273, respectively (p < 0.0001), and after the second vaccine dose, the highest (89%) in the m1273/m1273 group (p < 0.001). Individuals with systemic VAS achieved higher levels of antibodies irrespective of vaccine regimen. In conclusion, VAS serve as a strong predictor of long-term humoral immune response, and the heterologous ChAd/m1273 vaccine regimen provides an at least equal long-term humoral immune response compared with the standard vaccine regimens used in Denmark.

4.
Vaccine ; 40(38): 5631-5640, 2022 09 09.
Article in English | MEDLINE | ID: covidwho-1984213

ABSTRACT

BACKGROUND: Although several assays are used to measure anti-receptor-binding domain (RBD) antibodies induced after severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) vaccination, the assays are not fully comparable in practice. This study evaluated the immunogenicity of the BNT162b2 mRNA vaccine in healthy adults using two immunoassays. METHODS: This prospective cohort study included SARS-CoV-2-naïve adults, predominantly healthcare workers, aged 20-64 years, who received two BNT162b2 vaccine doses between March and May 2021. Blood samples were collected before the first vaccination (S0), before the second vaccination (S1), 4 weeks after the second vaccination (S2), and 6 months after the second vaccination (S3). anti-RBD antibodies were measured using the Architect SARS-CoV-2 IgG II Quant (Abbott Laboratory) and Elecsys anti-SARS-CoV-2 S (Roche Diagnostics) assays. RESULTS: Among the 385 participants, the geometric mean antibody titers (GMTs) on the Architect assay (AU/mL) were 7.5, 693, 7007, and 1030 for S0, S1, S2, and S3, respectively. The corresponding GMTs on the Elecsys assay (U/mL) were 0.40, 24, 928, and 659, respectively. The GMT ratio (S3/S2) was 0.15 on the Architect and 0.71 on the Elecsys assay. The correlation between antibody titers measured with the two assays were strong at all time points after vaccination (Spearman's correlation coefficient: 0.74 to 0.86, P < 0.01 for all). GMT was significantly lower in the older age group after vaccination (P < 0.01), with no significant differences according to sex. Seroprotection (≥5458 AU/mL on the Architect assay and ≥ 753 U/mL on the Elecsys) at each time point was 0 %, 1 %, 67 %, and 1 % on the Architect assay and 0 %, 1 %, 62 %, and 43 % on the Elecsys, respectively. CONCLUSIONS: Two BNT162b2 vaccine doses resulted in adequate anti-RBD antibody response, which varied by age. As the two assays showed different kinetics, the results of single immunoassays should be interpreted with caution.


Subject(s)
COVID-19 , Viral Vaccines , Adult , Aged , Antibodies, Viral , BNT162 Vaccine , COVID-19/prevention & control , Humans , Immunoassay , Japan , Prospective Studies , SARS-CoV-2 , Vaccination , Vaccines, Synthetic , mRNA Vaccines
5.
Virusdisease ; 33(2): 166-171, 2022 Jun.
Article in English | MEDLINE | ID: covidwho-1943381

ABSTRACT

Introduction: A serosurvey was designed to ascertain the extent of infection among police personnel in Mumbai, India, during the last week of January 2021, at the end of the first wave of the COVID-19 pandemic, and just before the introduction of vaccination. Methods: The survey was carried out to screen for SARS-CoV-2 among 3232 police personnel. Of the 3176 participants willing for blood sample collection, 3077 personnel were found to be eligible for testing antibodies against the SARS-CoV-2 virus using the Roche Diagnostics' Elecsys Anti-SARS-CoV-2 assay. Results: The overall seroprevalence was 74.1% (95% CI 72.5-75.6). Males (75.1%, 73.4-76.8) had significantly higher seroprevalence than females (69.8%, 66.0-73.3), 18-39 years age group (76.4%, 74.4-78.3) than 40-59 years age group (70.6%, 67.9-73.1), non-officers (75.2%, 73.5-76.7) than officers (63.8%, 58.2-69.0), and personnel without comorbidities (75.0%, 73.3-76.6) than with comorbidities (69.7%, 65.6-73.5). Additionally, personnel with resident members positive for COVID-19 (89.6%, 84.7-93.1), personnel having reported COVID-19 earlier (95.5%, 93.8-96.7), and personnel having PCR positivity earlier (96.4%, 94.7-97.6) had significantly higher seroprevalences than others. All other variables, including diabetes and blood glucose status, lipid levels and thyroid enzymes, were not significantly associated with the seroprevalence levels. Conclusions: Almost three-fourths of frontline police personnel had evidence of past COVID-19 infection at the end of the first wave in January 2021, just before the introduction of COVID-19 vaccination. These frontline non-healthcare essential workers are an important risk group, and amenable to rapid serosurveys. These findings may help in estimating transmission status in the general community, along with disease burden, aiding prioritization of healthcare services.

6.
Ann Clin Lab Sci ; 52(2): 332-335, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1787119

ABSTRACT

OBJECTIVE: Although real-time reverse transcription-PCR (RT-PCR) is the gold standard for diagnosing coronavirus disease 2019 (COVID-19), simpler and faster antibody detection tests can be complementary for diagnosis of COVID-19. To manage the COVID-19 pandemic, the need for serologic testing has increased. In this report, the newly developed antibody detection assays ACCEL ELISA COVID-19 (ACCEL) and Elecsys anti-SARS-CoV-2 (Elecsys) were evaluated. METHODS: Serum samples submitted for routine laboratory testing were analyzed (66 and 161 PCR-positive and PCR-negative samples). After the samples were aliquoted, antibody detection tests were performed using ACCEL and Elecsys assays. RESULTS: When detection of viral RNA using RT-PCR was set as the reference method for diagnosis of COVID-19, the sensitivity was 83.3% and 75.8, and the specificity was 96.9 and 99.4% in ACCEL and Elecsys, respectively. The true positivity rates of ACCEL and Elecsys assays were 57.1%/42.9%, 57.1%/28.6%, 77.8%/66.7%, and 97.1%/97.1% among the specimens collected ≤3, 4-7, 8-14, and >14 days after symptom onset, respectively. CONCLUSIONS: The ACCEL assay showed high sensitivity in samples collected within 7 days after symptom onset. Because many patients are asymptomatic in the early stage of SARS-CoV-2 infection, the ACCEL assay could be a good screening tool due to high sensitivity in the early stage of SARS-CoV-2 infection.


Subject(s)
COVID-19 , COVID-19/diagnosis , Enzyme-Linked Immunosorbent Assay/methods , Humans , Pandemics , SARS-CoV-2 , Sensitivity and Specificity
7.
Vaccines (Basel) ; 10(2)2022 Jan 26.
Article in English | MEDLINE | ID: covidwho-1648654

ABSTRACT

Coronavirus disease 2019 (COVID-19) vaccination began for healthcare workers in South Korea at the end of February 2021. This study investigated severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody responses after various COVID-19 vaccinations in healthcare workers. Blood specimens of 497 vaccinated healthcare workers were collected. Inoculated vaccines were ChAdOx1 (AstraZeneca/Oxford), BNT162b2 (Pfizer/BioNTech), JNJ-78436735 (Janssen), and mRNA-1273 (Moderna). Each specimen was tested for antibodies against SARS-CoV-2 using Elecsys Anti-SARS-CoV-2 S assay (Roche Diagnostics), SARS-CoV-2 IgG II Quant assay (Abbott), and R-FIND SARS-CoV-2 Neutralizing Antibody kit (SG medical Inc.). A questionnaire was used to investigate adverse events related to vaccination. We found that 99.5% of the subjects showed a 96-100% positive rate in all three antibody assays, regardless of the vaccine type. The antibody-positive rate of completed vaccination groups reached 96-100%, and antibody quantities significantly increased 2 weeks after vaccination. The antibody values measured approximately 3 months after BNT162b2 inoculation significantly correlated with adverse events.

8.
J Clin Lab Anal ; 36(1): e24182, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1568117

ABSTRACT

BACKGROUND: Interleukin-6 (IL-6) is a multifunctional cytokine associated with various diseases, including coronavirus disease (COVID-19). Although IL-6 levels can be assessed using serum samples, use of the AFIAS (Boditech Med Inc.) automated immunoassay analyzer enables quick and simple measurement of IL-6 levels in both serum and whole blood specimens. This study aimed to assess the correlation between IL-6 measurements obtained from the AFIAS IL-6 assay and Elecsys IL-6 assay (Roche Diagnostics). Additionally, utilization of the AFIAS IL-6 assay was evaluated. METHODS: The IL-6 levels from 113 serum samples quantified using two assay systems were evaluated for their degree of correlation. Meanwhile, the linearity, analytical sensitivity, and precision/reproducibility of the AFIAS IL-6 assay were also assessed. RESULTS: Quantification of IL-6 with the AFIAS IL-6 and Elecsys IL-6 assays showed excellent agreement (kappa 0.802) and were found to be correlated (y = -0.2781 + 1.068x; 95% confidence interval: 1.007-1.124). AFIAS IL-6 showed good analytical performances. IL-6 levels were significantly higher in deceased patients compared to those with non-complicated disease and those who were intubated (p = 0.002 and p < 0.0001, respectively). Finally, IL-6 levels more accurately predicted poor prognosis in patients, than did C-reactive protein (area under the curve, 0.716 vs. 0.634). CONCLUSION: The overall analytical performance of the AFIAS assay was comparable to that of the Elecsys IL-6 assay. In light of the ongoing COVID-19 pandemic, the AFIAS may be an attractive tool for measuring IL-6 levels.


Subject(s)
COVID-19/blood , COVID-19/diagnosis , Interleukin-6/blood , SARS-CoV-2/immunology , C-Reactive Protein/analysis , Diagnostic Tests, Routine/methods , Female , Humans , Immunoassay/methods , Male , Middle Aged , Sensitivity and Specificity
9.
J Infect Chemother ; 28(2): 266-272, 2022 Feb.
Article in English | MEDLINE | ID: covidwho-1560482

ABSTRACT

INTRODUCTION: The usefulness of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody tests in asymptomatic individuals has not been well validated, although they have satisfied sensitivity and specificity in symptomatic patients. In this study, we investigated the significance of IgM and IgG antibody titers against SARS-CoV-2 in the serum of asymptomatic healthy subjects. METHODS: From June 2020, we recruited 10,039 participants to the project named the University of Tokyo COVID-19 Antibody Titer Survey (UT-CATS), and measured iFlash-SARS-CoV-2 IgM and IgG (YHLO IgM and IgG) titers in the collected serum. For the samples with increased IgM or IgG titers, we performed additional measurements using Elecsys Anti-SARS-CoV-2 Ig (Roche total Ig) and Architect SARS-CoV-2 IgG (Abbott IgG) and investigated the reactivity to N, S1, and receptor binding domain (RBD) proteins. RESULTS: After setting the cutoff value at 5 AU/mL, 61 (0.61%) were positive for YHLO IgM and 104 (1.04%) for YHLO IgG. Few samples with elevated YHLO IgM showed reactivity to S1 or RBD proteins, and IgG titers did not increase during the follow-up in any samples. The samples with elevated YHLO IgG consisted of two groups: one reacted to S1 or RBD proteins and the other did not, which was reflected in the results of Roche total Ig. CONCLUSIONS: In SARS-CoV-2 seroepidemiological studies of asymptomatic participants, sufficient attention should be given to the interpretation of the results of YHLO IgM and IgG, and the combined use of YHLO IgG and Roche total Ig might be more reliable.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Healthy Volunteers , Humans , Immunoglobulin G , Immunoglobulin M , Seroepidemiologic Studies
10.
Vaccines (Basel) ; 9(11)2021 Nov 11.
Article in English | MEDLINE | ID: covidwho-1512746

ABSTRACT

Robust assay development for SARS-CoV-2 serological testing requires assessment of asymptomatic and non-hospitalised individuals to determine if assays are sensitive to mild antibody responses. Our study evaluated the performance characteristics of two high-throughput SARS-CoV-2 IgG nucleocapsid assays (Abbott Architect and Roche) and The Binding Site (TBS) Anti-Spike IgG/A/M ELISA kit in samples from healthcare workers (HCWs). The 252 samples were collected from multi-site NHS trusts and analysed for SARS-CoV-2 serology. Assay performance was evaluated between these three platforms and ROC curves were used to redefine the Abbott threshold. Concordance between Abbott and TBS was 66%. Any discrepant results were analysed using Roche, which showed 100% concordance with TBS. Analysis conducted in HCWs within 58 days post-PCR result demonstrated 100% sensitivity for both Abbott and Roche. Longitudinal analysis for >100 days post-PCR led to sensitivity of 77.2% and 100% for Abbott and Roche, respectively. A redefined Abbott threshold (0.64) increased sensitivity to 90%, producing results comparable to TBS and Roche. The manufacturer's threshold set by Abbott contributes to lower sensitivity and elevated false-negative occurrences. Abbott performance improved upon re-optimisation of the cut-off threshold. Our findings provided evidence that TBS can be used as bespoke alternative for SARS-CoV-2 serology analysis where high-throughput platforms are not feasible on site.

11.
Microbiol Spectr ; 9(2): e0039121, 2021 10 31.
Article in English | MEDLINE | ID: covidwho-1443360

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies are an excellent indicator of past COVID-19 infection. As the COVID-19 pandemic progresses, retained sensitivity over time is an important quality in an antibody assay that is to be used for the purpose of population seroprevalence studies. We compared 5,788 health care worker (HCW) serum samples by using two serological assays (Abbott SARS-CoV-2 anti-nucleocapsid immunoglobulin G (IgG) and Roche anti-SARS-CoV-2 anti-nucleocapsid total antibody) and a subset of samples (all Abbott assay positive or grayzone, n = 485) on Wantai SARS-CoV-2 anti-spike antibody enzyme-linked immunosorbent assay (ELISA). For 367 samples from HCW with a previous PCR-confirmed SARS-CoV-2 infection, we correlated the timing of infection with assay results. Overall, seroprevalence was 4.2% on Abbott and 9.5% on Roche. Of those with previously confirmed infection, 41% (150/367) and 95% (348/367) tested positive on Abbott and Roche, respectively. At 21 weeks (150 days) after confirmed infection, positivity on Abbott started to decline. Roche positivity was retained for the entire study period (33 weeks). Factors associated (P ≤ 0.050) with Abbott seronegativity in those with previous PCR-confirmed infection included sex (odds ratio [OR], 0.30 male ; 95% confidence interval [CI], 0.15 to 0.60), symptom severity (OR 0.19 severe symptoms; 95% CI, 0.05 to 0.61), ethnicity (OR, 0.28 Asian ethnicity; 95% CI, 0.12 to 0.60), and time since PCR diagnosis (OR, 2.06 for infection 6 months previously; 95% CI, 1.01 to 4.30). Wantai detected all previously confirmed infections. In our population, Roche detected antibodies up to at least 7 months after natural infection with SARS-CoV-2. This finding indicates that the Roche total antibody assay is better suited than Abbott IgG assay to population-based studies. Wantai demonstrated high sensitivity, but sample selection was biased. The relationship between serological response and functional immunity to SARS-CoV-2 infection needs to be delineated. IMPORTANCE As the COVID-19 pandemic progresses, retained sensitivity over time is an important quality in an antibody assay that is to be used for the purpose of population seroprevalence studies. There is a relative paucity of published literature in this field to help guide public health specialists when planning seroprevalence studies. In this study, we compared results of 5,788 health care worker blood samples tested by using two assays (Roche and Elecsys, anti-nucleocapsid antibody) and by testing a subset on a third assay (Wantai enzyme-linked immunosorbent assay [ELISA] anti-spike antibody). We found significant differences in the performance of these assays, especially with distance in time from PCR-confirmed COVID-19 infection, and we feel these results may significantly impact the choice of assay for others conducting similar studies.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/immunology , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , Cross-Sectional Studies , Enzyme-Linked Immunosorbent Assay , Female , Health Personnel/statistics & numerical data , Humans , Immunoglobulin G/blood , Male , Middle Aged , Phosphoproteins/immunology , Sensitivity and Specificity , Seroepidemiologic Studies , Young Adult
12.
EBioMedicine ; 70: 103502, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1330765

ABSTRACT

BACKGROUND: Since 2020 SARS-CoV-2 spreads pandemically, infecting more than 119 million people, causing >2·6 million fatalities. Symptoms of SARS-CoV-2 infection vary greatly, ranging from asymptomatic to fatal. Different populations react differently to the disease, making it very hard to track the spread of the infection in a population. Measuring specific anti-SARS-CoV-2 antibodies is an important tool to assess the spread of the infection or successful vaccinations. To achieve sufficient sample numbers, alternatives to venous blood sampling are needed not requiring medical personnel or cold-chains. Dried-blood-spots (DBS) on filter-cards have been used for different studies, but not routinely for serology. METHODS: We developed a semi-automated protocol using self-sampled DBS for SARS-CoV-2 serology. It was validated in a cohort of matched DBS and venous-blood samples (n = 1710). Feasibility is demonstrated with two large serosurveys with 10247 company employees and a population cohort of 4465 participants. FINDINGS: Sensitivity and specificity reached 99·20% and 98·65%, respectively. Providing written instructions and video tutorials, 99·87% (4465/4471) of the unsupervised home sampling DBS cards could be analysed. INTERPRETATION: DBS-sampling is a valid and highly reliable tool for large scale serosurveys. We demonstrate feasibility and accuracy with a large validation cohort including unsupervised home sampling. This protocol might be of big importance for surveillance in resource-limited settings, providing low-cost highly accurate serology data. FUNDING: Provided by Bavarian State Ministry of Science and the Arts, LMU University-Hospital; Helmholtz-Centre-Munich, German Ministry for Education and Research (project01KI20271); University of Bonn; University of Bielefeld; the Medical Biodefense Research Program of Bundeswehr-Medical-Service; Euroimmun, RocheDiagnostics provided discounted kits and machines.


Subject(s)
Antibodies, Viral/immunology , Biological Assay/methods , COVID-19 Serological Testing/methods , COVID-19/blood , COVID-19/immunology , Dried Blood Spot Testing/methods , SARS-CoV-2/immunology , Asymptomatic Infections , Cohort Studies , Humans , Longitudinal Studies , Sensitivity and Specificity , Specimen Handling/methods , Vaccination/methods
14.
Diagn Microbiol Infect Dis ; 99(1): 115197, 2021 Jan.
Article in English | MEDLINE | ID: covidwho-1023527

ABSTRACT

Automated assays for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies in coronavirus disease 2019 (COVID-19) diagnostics have recently come available. We compared the performance of the Elecsys® Anti-SARS-CoV-2 and LIAISON® SARS-CoV-2 S1/S2 IgG tests. The seroconversion panel comprised of 120 samples from 13 hospitalized COVID-19 patients. For the sensitivity and specificity testing, samples from COVID-19 outpatients >15 days after positive nucleic acid amplification test (NAAT) result (n = 35) and serum control samples collected before the COVID-19 era (n = 161) were included in the material. Samples for the detection of possible cross-reactions were also tested. Based on our results, the SARS-CoV-2 antibodies can be quite reliably detected 2 weeks after NAAT positivity and 3 weeks after the symptom onset with both tests. However, since some COVID-19 patients were positive only with Elecsys®, the antibodies should be screened against N-antigen (Elecsys®) and reactive samples confirmed with S antigen (LIAISON®), but both results should be reported. In some COVID-19 patients, the serology can remain negative.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/immunology , Coronavirus Nucleocapsid Proteins/immunology , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , Aged , COVID-19/blood , COVID-19/diagnosis , COVID-19 Nucleic Acid Testing , Cross Reactions , Female , Humans , Kinetics , Male , Middle Aged , Phosphoproteins/immunology , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Seroconversion , Young Adult
15.
Hepatol Res ; 50(10): 1196-1200, 2020 Oct.
Article in English | MEDLINE | ID: covidwho-689096

ABSTRACT

AIM: Coronavirus disease 2019 (COVID-19) is a serious public health concern, with unclarified prevalence in Japan. Concomitant liver disease could increase the severity of COVID-19 disease, and chronic liver disease patients sometimes require frequent admission and gastrointestinal endoscopy. Thus, clarifying the prevalence of asymptomatic COVID-19 in outpatients with liver disease is essential for preventing nosocomial infections. We aimed to clarify the time-dependent changes in COVID-19 seroprevalence in liver disease outpatients, who were asymptomatic for COVID-19, in an area of Japan experiencing a second wave of COVID-19. METHODS: We included the preserved sera of 100, 300, and 300 consecutive liver disease outpatients, who were asymptomatic for COVID-19, from May 2019, March 2020, and May 2020, respectively. The sera were analyzed immunochromatographically to detect immunoglobulin G against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (KURABO) and by Elecsys Anti-SARS-CoV-2-assay (Roche Diagnostics). RESULTS: Analysis of 100 cases from May 2019, before COVID-19 became pandemic, revealed that the specificity of immunochromatographic tests and Elecsys were 98% (95% confidence interval [CI], 93-99.8%) and 100% (95% CI, 97-100%), respectively. Analysis of 300 cases from March 2020 revealed a seroprevalence of 0.3% (1/300; 95% CI, 0-1.8%) for COVID-19 by Elecsys Anti-SARS-CoV-2 assay. Analysis of 300 cases from May 2020 revealed a seroprevalence of 0% (0/300; 95% CI, 0-1.0%). CONCLUSIONS: The Elecsys Anti-SARS-CoV-2 assay has high specificity. The cumulative seroprevalence of COVID-19 by the Elecsys Anti-SARS-CoV-2 assay in outpatients with liver disease in Sapporo, who were asymptomatic for COVID-19, was 0.17% (1/600; 95% CI, 0.0-0.9%) until May 2020.

SELECTION OF CITATIONS
SEARCH DETAIL